800-2200kW 10500V Open Yuchai Engine Diesel Genset with Full-flow Oil Cooler
Small friction loss
Reliability of the sealing
Long service life
According to the ISO 8528-5 standard
- Standard
- Performance
STANDARD
- ISO 8528: AC generator set driven by reciprocating internal combustion engine
- IEC 60034-1: Basic technical requirements for rotating electrical machines
- YD/T 502: Communication diesel generator set
- GB/T 20136-2006: General test method for internal combustion engine power station
- All engine systems have passed prototype and factory tests.
ADVANTAGE
- The engine body, cylinder head, crankshaft connecting rod and other main structures have been tested for a long time to ensure the high reliability of the whole machine.
- Adopt the cylinder head integrated water outlet design to reduce the sealing surface and improve the reliability of the sealing
- The full-flow oil cooler is adopted to increase the heat dissipation efficiency by 30%, which effectively reduces the oil temperature, so that the oil lubricates the parts at a reasonable temperature and reduces friction loss.
- The piston is cooled by an internal cooling oil passage, which effectively reduces the temperature of the piston and has a long service life.
- Meet the requirements of performance level G3 of generator set
- The transient response of the unit is tested according to the ISO 8528-5 standard, and the single-step loading rate can reach up to 60%.
All engine systems have passed prototype and factory tests.
PERFORMANCE
Parameter | Unit | Performance | ||
Frequency drop | % | ≤3 | ||
Steady-state frequency band | % | ≤0.5 | ||
Relative frequency setting drop range | % | ≥3.5 | ||
Relative frequency setting rising range | % | ≥2.5 | ||
Transient frequency deviation | 100% sudden reduction power | % | ≤+10 | |
Sudden power | ≤-7 | |||
Frequency recovery time | s | ≤3 | ||
Relative frequency tolerance band | % | 2 | ||
Steady-state voltage deviation | % | ≤±1 | ||
Voltage unbalance | % | 1 | ||
Transient voltage deviation | 100% sudden reduction power | % | ≤+20 | |
Sudden power | ≤-15 | |||
Voltage recovery time | s | ≤4 | ||
Voltage modulation | % | 0.3 | ||
Relative voltage setting range | % | ≤±5 | ||
Voltage setting rate of change | %/s | 0.2~1 | ||
Telephone harmonic factor | THF | % | <2 | |
Phone influencing factors | TIF | —— | <50 |
DRAWING
OPERATING ENVIRONMENT
The main power (PRP) is the maximum power that the unit can continuously operate with variable load under standard environment (atmospheric pressure, relative humidity, ambient temperature) conditions, and allow 10% overload operation for 1 hour every 12 hours.
- Altitude: ≤1000m (when >1000m, power correction is required)
- Ambient temperature: 40°C (when >40°C, power correction is required)
- Relative humidity: ≤60%
- When the on-site operating conditions of the diesel generating set doesn’t meet the above conditions, the output power of the generator set must be corrected, and finally corrected coefficient, please consult us.
Genset Model | Prime Power(kW) | Standby Power(kW) | Power Factor | Rated Voltage | Frequency | Dimension (L×W×H) (mm) | Weight(kg) | Engine Model | Number of Cylinders | Bore×Stroke(mm) | Displacement(L) | Fuel Consumption(g/kW) | Speed | Cooling System | Starting Method |
Yuchai Genset Open Style(10500V) | |||||||||||||||
ATYOH-Y800F | 800 | 880 | 0.8 | 10500V | 50HZ | 5050L×1770W×2526H | 10850 | YC6C1320-D31 | 6 | 200*210 | 39.58 | <220 | 1500 | Water Cooling | Electrical Starting |
ATYOH-Y800FG | 800 | 880 | 0.8 | 10500V | 50HZ | 5050L×1770W×2526H | 10550 | YC12VTD1350-D30 | 12 | 152*180 | 39.20 | <220 | 1500 | Water Cooling | Electrical Starting |
ATYOH-Y900F | 900 | 990 | 0.8 | 10500V | 50HZ | 5050L×1770W×2526H | 10850 | YC6C1520-D31 | 6 | 200*210 | 39.58 | <220 | 1500 | Water Cooling | Electrical Starting |
ATYOH-Y900FG | 900 | 990 | 0.8 | 10500V | 50HZ | 5050L×1770W×2526H | 10600 | YC12VTD1500-D30 | 12 | 152*180 | 39.20 | <220 | 1500 | Water Cooling | Electrical Starting |
ATYOH-Y1000F | 1000 | 1100 | 0.8 | 10500V | 50HZ | 5050L×1770W×2526H | 10850 | YC6C1660-D30 | 6 | 200*210 | 39.58 | <220 | 1500 | Water Cooling | Electrical Starting |
ATYOH-Y1000FG | 1000 | 1100 | 0.8 | 10500V | 50HZ | 6260L×2550W×2890H | 17700 | YC12VC1680-D31 | 12 | 200*210 | 79.17 | <210 | 1500 | Water Cooling | Electrical Starting |
ATYOH-Y1000FGH | 1000 | 1100 | 0.8 | 10500V | 50HZ | 5050L×1770W×2526H | 10600 | YC12VTD1680-D30 | 12 | 152*180 | 39.20 | <220 | 1500 | Water Cooling | Electrical Starting |
ATYOH-Y1100F | 1100 | 1200 | 0.8 | 10500V | 50HZ | 6260L×2555W×2890H | 13520 | YC12VTD1830-D30 | 12 | 152*180 | 39.20 | <220 | 1500 | Water Cooling | Electrical Starting |
ATYOH-Y1200F | 1200 | 1320 | 0.8 | 10500V | 50HZ | 6260H×2555W×2890L | 17800 | YC12VC2070-D31 | 12 | 200*210 | 79.17 | <220 | 1500 | Water Cooling | Electrical Starting |
ATYOH-Y1200FG | 1200 | 1320 | 0.8 | 10500V | 50HZ | 6260L×2555W×2890H | 13620 | YC12VTD2000-D30 | 12 | 152*180 | 39.20 | <220 | 1500 | Water Cooling | Electrical Starting |
ATYOH-Y1350F | 1350 | 1485 | 0.8 | 10500V | 50HZ | 6260L×2555H×2890W | 17900 | YC12VC2270-D31 | 12 | 200*210 | 79.17 | <220 | 1500 | Water Cooling | Electrical Starting |
ATYOH-Y1500F | 1500 | 1650 | 0.8 | 10500V | 50HZ | 6260L×2555W×2890H | 18100 | YC12VC2510-D31 | 12 | 200*210 | 79.17 | <210 | 1500 | Water Cooling | Electrical Starting |
ATYOH-Y1700F | 1700 | 1800 | 0.8 | 10500V | 50HZ | 6260L×2555W×2890H | 18300 | YC12VC2700-D31 | 12 | 200*210 | 79.17 | <210 | 1500 | Water Cooling | Electrical Starting |
ATYOH-Y1800F | 1800 | 1980 | 0.8 | 10500V | 50HZ | 7750L×2650W×3050H | 22000 | YC16VC3000-D31 | 16 | 200*210 | 105.56 | <210 | 1500 | Water Cooling | Electrical Starting |
ATYOH-Y2000F | 2000 | 2200 | 0.8 | 10500V | 50HZ | 7750L×2650W×3050H | 23000 | YC16VC3300-D31 | 16 | 200*210 | 105.56 | <210 | 1500 | Water Cooling | Electrical Starting |
ATYOH-Y2200F | 2200 | 2420 | 0.8 | 10500V | 50HZ | 7700L×2615W×3250H | 24000 | YC16VC3600-D31 | 16 | 200*210 | 105.56 | <210 | 1500 | Water Cooling | Electrical Starting |