720-1800kW 10500V High Performance Open Style Perkins Genset
High-performance
Standardized design
Small size, compact structure
Independent direct fuel injection system
- Standard
- Performance
STANDARD
- ISO 8528: AC generator set driven by reciprocating internal combustion engine
- IEC 60034-1: Basic technical requirements for rotating electrical machines
- YD/T 502: Communication diesel generator set
GB/T 20136-2006: General test method for internal combustion engine power station
ADVANTAGE
- Small size, compact structure, sophisticated craftsmanship, beautiful appearance. low noise, excellent emission indicators.
- Independent direct fuel injection system, low fuel consumption.
- Adopt a closed-circulation cooling system and install a high-efficiency radiator, which can still maintain normal when the ambient temperature is as high as 52℃.
- High-performance shock absorption system and rigid base, low vibration.
- Standardized design, strong versatility of parts, easy to install and easy to maintain.
- Maintenance-free battery, with quick start performance.
- Intelligent parallel expansion function.
PERFORMANCE
Parameter | Unit | Performance | ||
Frequency drop | % | ≤5 | ||
Steady-state frequency band | % | ≤1.5 | ||
Relative frequency setting drop range | % | ≥3.5 | ||
Relative frequency setting rising range | % | ≥2.5 | ||
Transient frequency deviation | 100% sudden reduction power | % | ≤+12 | |
Sudden power | ≤-10 | |||
Frequency recovery time | s | ≤5 | ||
Relative frequency tolerance band | % | 2 | ||
Steady-state voltage deviation | % | ≤±2.5 | ||
Voltage unbalance | % | 1 | ||
Transient voltage deviation | 100% sudden reduction power | % | ≤+25 | |
Sudden power | ≤-20 | |||
Voltage recovery time | s | ≤6 | ||
Voltage modulation | % | 0.3 | ||
Relative voltage setting range | % | ≤±5 | ||
Voltage setting rate of change | %/s | 0.2~1 | ||
Telephone harmonic factor | THF | % | <2 | |
Phone influencing factors | TIF | / | <50 |
DRAWING
OPERATING ENVIRONMENT
The main power (PRP) is the maximum power that the unit can continuously operate with variable load under standard environment (atmospheric pressure, relative humidity, ambient temperature) conditions, and allow 10% overload operation for 1 hour every 12 hours.
- Altitude: ≤1000m (when >1000m, power correction is required)
- Ambient temperature: 40°C (when >40°C, power correction is required)
- Relative humidity: ≤60%
- When the on-site operating conditions of the diesel generating set doesn’t meet the above conditions, the output power of the generator set must be corrected, and finally corrected coefficient, please consult us.
Genset Model | Genset Prime Power(kW) | Genset Standby Power(kW) | Power Factor | Rated Voltage | Frequency | Dimension (L×W×H) (mm) | Weight(kg) | Engine Model | Number of Cylinders | Bore×Stroke(mm) | Displacement(L) | Fuel Consumption(g/kW) | Speed | Cooling System | Starting Method |
Perkins Engine Generator Open Style(10500V) | |||||||||||||||
ATYOH-P720 | 720 | 790 | 0.8 | 10500V | 50HZ | 5425L×2046W×2430H | 7050 | 4008TAG1A | 8 | 160*190 | 30.561 | <210 | 1500 | Water Cooling | Electrical Starting |
ATYOH-P800 | 800 | 880 | 0.8 | 10500V | 50HZ | 5425L×2046W×2430H | 7450 | 4008TAG2 | 8 | 160*190 | 30.561 | <210 | 1500 | Water Cooling | Electrical Starting |
ATYOH-P800 | 800 | 880 | 0.8 | 10500V | 50HZ | 5425L×2046W×2430H | 7450 | 4008TAG2A | 8 | 160*190 | 30.561 | <210 | 1500 | Water Cooling | Electrical Starting |
ATYOH-P900 | 900 | 1000 | 0.8 | 10500V | 50HZ | 5694L×1970W×2431H | 13350 | 4008-30TAG3 | 8 | 160*190 | 30.561 | <210 | 1500 | Water Cooling | Electrical Starting |
ATYOH-P1000 | 1000 | 1100 | 0.8 | 10500V | 50HZ | 5694L×1970W×2431H | 13350 | 4012-46TAG0A | 12 | 160*190 | 45.842 | <210 | 1500 | Water Cooling | Electrical Starting |
ATYOH-P1000G | 1000 | 1100 | 0.8 | 10500V | 50HZ | 5694L×1970W×2431H | 13350 | 4012-46TWG2A | 12 | 160*190 | 45.842 | <220 | 1500 | Water Cooling | Electrical Starting |
ATYOH-P1100 | 1100 | 1200 | 0.8 | 10500V | 50HZ | 5903L×2192W×2554H | 13723 | 4012-46TAG1A | 12 | 160*190 | 45.842 | <205 | 1500 | Water Cooling | Electrical Starting |
ATYOH-P1200 | 1200 | 1320 | 0.8 | 10500V | 50HZ | 5720L×2192W×2554H | 13823 | 4012-46TAG2A | 12 | 160*190 | 45.842 | <205 | 1500 | Water Cooling | Electrical Starting |
ATYOH-P1320 | 1320 | 1450 | 0.8 | 10500V | 50HZ | 5741L×2164W×2642H | 14417 | 4012-46TAG3A | 12 | 160*190 | 45.842 | <210 | 1500 | Water Cooling | Electrical Starting |
ATYOH-P1480 | 1480 | 1600 | 0.8 | 10500V | 50HZ | 6648L×2135W×2645H | 15550 | 4016TAG1A | 16 | 160*190 | 61.123 | <220 | 1500 | Water Cooling | Electrical Starting |
ATYOH-P1600 | 1600 | 1800 | 0.8 | 10500V | 50HZ | 6648L×2135W×2645H | 15550 | 4016TAG2A | 16 | 160*190 | 61.123 | <215 | 1500 | Water Cooling | Electrical Starting |
ATYOH-P1800 | 1800 | 2000 | 0.8 | 10500V | 50HZ | 6720L×2200W×2722H | 16250 | 4016-61TRG3 | 16 | 160*190 | 61.123 | <215 | 1500 | Water Cooling | Electrical Starting |